Alternating Current (AC). Any electrical waveform that exhibits alternating (reversing) current polarity. In electrofishing, the electrodes alternate as anode and cathode at the waveform frequency (Hertz or cycles per second).

Anode. The electrode exhibiting positive polarity in Direct Current (DC) and pulsed DC electrofishing systems, or the momentary positive electrode with Alternating Current (AC).

B

Bonding. The permanent mechanical joining of conductive materials to ensure a reliable, low-resistance electrical connection.

Branch Circuit. The main conductors located between the pulsator (or generator if there is no pulsator) and the electrodes. Electrical energy is transmitted through the branch circuit to the electrodes.

C

Cathode. The electrode exhibiting negative polarity in DC and pulsed DC electrofishing systems, or the momentary negative electrode with AC.

Circuit Breakers. Devices that automatically open the circuit and stop the flow of current when the current exceeds an acceptable magnitude. Circuit breakers protect the equipment, not the operator.

Conductor. An object or type of material that allows the flow of charge (electrical current). Wire, cable, and other metal hardware (e.g., boat hulls, bolts, screws, guard rails, insulated wires, engine cowls, and fish-holding tanks) are examples of conductors.

Condulet (Junction Box). A container for electrical connections that is meant to deter accidental touching of the connections and to protect the wiring from mechanical damage and weather. Condulets usually connect to conduit or electric cables.

D

Direct Current (DC). An electrical waveform with unidirectional (non-reversing) polarity and either constant or variable amplitude.

E

Electrical Continuity. Refers to being part of a complete or connected system that can conduct an electric current. All significantly sized metal surfaces in watercraft should be in electrical continuity by using wired or bonded connections.

Electrocution. Injury or death caused by an electric shock.

Electrodes. Metal objects used to deliver the electrical energy from the electrofishing unit circuitry into the water. Common materials used for electrodes include stainless steel and other steel alloys, aluminum, and galvanized steel. Electrodes come in a wide variety of shapes and sizes. When using direct current, the electrofishing unit contains an anode electrode(s) and a cathode electrode(s).

Electrofishing Unit. The gear used for electrofishing. At a minimum, the unit consists of an energy source, emergency stop switch, conductors, and electrodes. The unit may also include a pulsator, metering, and auxiliary circuits for lighting, live well pumps, etc. Two general categories of electrofishing units are watercraft (boat/raft) and portable (used when wading).

Electrosedation. The use of electricity to induce a relaxed, calm condition in fish, making operations such as egg-taking, examination, and attachment of transmitters simpler. See Exhibit 1 to 241 FW 6 for more information.

Electroshock. The perception of electrical current.

Emergency Stop Switch (“Kill Switch”). A switch that shuts off system power when pressure is applied. “Mushroom” or “slap-switch” style switch configurations make it easier to activate an emergency stop.

FNone.
G

Ground. An electrical connection between an electrical circuit and the earth or to some other conducting object, such as a boat hull.

(1) For watercraft electrofishing, the metal boat hull or rowing frame (raft) are the primary ground connections to which all other significant metal surfaces (generator, pulsator, metal rails, metal cord reels, etc.) are securely wired or bonded so that there are not any differential voltages to create a shock hazard. Small isolated pieces of metal (such as metal brackets on the operator seat) do not need to be wired or bonded.

(2) For boats with non-conductive hulls, a metal strip/plate is used as the primary ground connection.

HNone.
I

International Electrotechnical Commission (IEC). The group that sets international standards for electrical products.

Isolation Transformer. A transformer that has no wired circuit between its primary and secondary windings (i.e., infinite resistance). We use isolation transformers to allow the generator’s frame to function as the primary ground for the electrofishing system independent of a neutral connection. Incorporating an isolation transformer in the circuit between the generator and pulsator allows the use of a generator with the neutral connection intact. 

J -MNone.
N

National Electrical Manufacturers Association (NEMA). The trade association that sets common standards for electrical products.

Netter. The person who nets the fish or other aquatic organisms during electrofishing operations.

Neutral Connection. An electrical connection between the generator windings and the generator case (generator exterior). Most generators provide access to the internal windings that allow the user to ground the output terminals to the generator frame. Depending on the generator’s design, this connection may be a single jumper between two wire lugs or a complex, multi-wire interconnection. It is often necessary to remove the neutral connection or purchase a generator without a neutral connection (“floating neutral generator”) to avoid the malfunction of certain types of pulsators. Do not confuse the neutral connection with the equipment grounding circuits that must never be removed. If the neutral connection must be removed, seek professional assistance.

ONone.
P

Prod Pole. A hand-held, moveable electrode used in watercraft electrofishing, often larger than backpack electrode poles.

Pulsator (control box). The control unit that converts the input power (AC or DC) to appropriate waveforms of DC, pulsed DC, or AC for delivery to the electrodes. The pulsator is also called the control box.

Pulsed Direct Current (PDC). A modification of DC in which the waveform transitions from zero to a maximum (voltage, current, or power) at regular intervals.

QNone.
RRoot-Mean-Square (RMS). A precise measurement of AC voltage or current that allows for direct calculations of power. It approximates DC average voltage or average current.
S

Safety Switch (“Deadman Switch”). A secondary circuit, less than 24 volts, that requires constant manual pressure to close the circuit. It allows electrical current to flow in the main electrofishing circuit.

SOOW Cable. Letters in ‘SOOW’ stand for cable properties. The ‘S’ means ‘Service’ (heavy-duty grade). The ‘OO’ means the cable has oil-resistant conductor insulation and jacketing. The ‘W’ means the cable is weather and water resistant. The SOOW cable resists oil, solvents, water, ozone, aging, and abrasion. It is also flame retardant, flexible, and durable and rated at 600 V RMS. There is also SJOOW cable (‘J’ for “Junior”) that is rated at 300 V RMS.

TThrowable Anode. A portable, hand-held electrode typically used in conjunction with tow-barge or watercraft electrofishing that may be thrown into habitats and retrieved via the power cord. The effectiveness of throwable anodes depends on the attraction (galvanotaxis) response.
U- VNone.
W

Watertight (weatherproof).  An enclosure that is more protected than one called “weather-resistant” (e.g., NEMA type 4 and 4X, IEC IP56).